Home > Buy Now > Dehumidifier > Shipbuilding Type Dehumidifier
 


Korea Techno Co., Ltd.
 
icon Introduction
icon Patents & Technologies
icon Dehumidifier
icon Humidifier
icon Heater
icon Etc.

line

icon Company Profile
icon Selling Leads
icon Index
icon Bulletin Board
icon Guest Book
icon e-Book

line


icon To Korean Page
icon To Chinese Page




visitors: 12788
 
Contact us
Korea Techno Co., Ltd.
[Korea]
Address:
1-11 Baesuck-ri, Paju-eup, Paju-si, Gyeonggi-do 413-861 Korea
Phone:
82-31-9543555
Contact name:
Sung Lim. KIM , Export Team Manager
Inquire now









Korea Techno Co., Ltd.
 
Patents & Technologies

Shipbuilding Type Dehumidifier

Inquire now

Shipbuilding Type Dehumidifier

Click to enlarge image


* Rainwater-Dust-Microbes Intercepting New Removers

[Perfect Protect Louver]

* Purpose of use

The remover assembly is 99.9% effective at removing wind driven rain and fog particles.

 

A. The vertical chevron blade and hook provide maximum elimination with minimum resistance
B. As the air passes easily over the curve of the blade, the hook.
C. Captures the particulate, and gravity carries the particles into the drain pan and out of the remover.

 

KTPL4 REMOVER can prevent the penetration of rainwater by 99.9 percent in case rainwater of 360mm per hour accompanies the wnd of 50mph.

KTPL4 REMOVER displays 99.9 percent interception efficiency in the generation room and water-cooled electric motor room adopted by the world famous oil drilling ship company.
The innovative NEW KTPL12 REMOVER has veen strictly tested in Data County, Florida which can offer the hurricane code and proved its efficiency in the wind velocity of 110mph and the rainfall of 770mm per hour.
KTPL8 REMOVER is designed to collect the sand particle and can remove it without using fan.
KTPL8 displays the interception efficiency of 96 percent in the 3-4 time quicker wind velocity compared to the other sand-removing equipments.

 

 

 

 

 

KTPL NEW REMOVER can perfectly exclude the occurrence of rainwater from the wind accompanying with severe fog and rainwater, adopted to the tower type air conditioner. (Keeping the loss of low static pressure and the stability of strength)
In case adopted to the air conditioning system of hospital, it can prevent the mildews and the microbes from growing in the ventilation system and the air conditioner by removing the rainwater and dust flowing into the inside of system.

 

* Where is the perfect louver to be installed in the ship?



A : Protected areas : used for shutting off from the strong wind and the heavy rain in the storm and fog and incidental salt
B : Lower levels : used for shutting off from the salty spray near the surface of seawater where the severe circumstances occurs continuously
C : Intermediate levels : used for shutting off from the rain, heavy rain, and salty spray in the upper structure and the ship body

Heavy rain-intercepting effect accompanying with the strong wind. Heavy rain, spray and fog-intercepting effect.

 

 

* Perfect louver and 6"general eliminator test comparison curve

 

  • The pressure loss ratio is based on the experiment fixed to the wall and the 24" x 24" Louver test.
* Rainwater and fog removing efficiency

Data based on 24" x 24" (610 x 610mm) louver.
Test duration 15minutes.

  • Ventilation fan used to simulate intake air condition from HVAC equipment
* Pressure Drop

* New Removers(perfect protect louver) Selection

[Use and efficiency of perfect protect louver]


Related Keywords: dehumidifier , cooler system


Inquire now