* Environmental Control Unit
To maintain the constant temperature and humidilty of the space that the customer desires, we have maximized the sensible heat rate. With minimization & weight-lightening, we have achieved modest operation, so stable temperature & humidity level is maintained in any circumstances. (Air, Water, Cycle-Cooled, CPU-(Chiller)Type)
|
* Air shower

It offers showering through the use of high speed, clean, germfree air to the entrance of clean room or detailed-workshop. It is a device which can completely realize the clean room purity level, it is an energy saving device and its door is automatic. Also, Manual selection is possible.
|
* Air Control Unit
This is a device made to economically realize the class 100~100,000. Also, it is a compact unit with both cleaning functions and maintaining a constant temperature & humidity.
The airflow makes a uniform and stable air current, which prevents pollution from occuring again through turbulent flow. So it can satisfy any clean room condition. With a compact exterior, there is no need for a separate machine room making it quite economical.

All conditioned ICR and BCR are possible by efficiently systematizing the AIR CONTROL UNIT, CLEAN UNIT, and SUPPLY UNIT
- Characteristics
-
- Can produce the stable air current of down flow
- Can respond to clean room in any condition by combining unit
- Doesn't need the supply exhaust ducts and the machine room
- Easy for operation and maintenance since it is small-sized
- Raising the indoor ceiling and making the wide working place by not using duct
- the operation noise level is quite low (below 60dB) because the number of circulation is small
- Free for changing, moving and remodelling class after installation.
- Not hard at all for th construction and design because of no duct construction
- The sharp reduction of construction period is possible including panel construction
- Can save significantly the facility cost and running cost in case of the large-size clean room
- Class setting and operation by building is possible
* Unit Standard Specification
1. Air control unit (ACU : general air-conditioning and cleaning or open-air blowing-in unit)

2. Clean Unit (CU. Cleaning Unit)

3. Outdoor UNIT[CDU : Built in refrigerator, Fan, Oil heater]
4. Open-air introduction UNIT[OAU]
5. Supply UNIT
* Standard specification
(according to the size of Class and room of system)
Line type clean room system is our company's independent system designed as a result of high credibility and through cost performance for a long time. It can operate in a short period with an easy design to strict condition and an extremely simplified site construction.
Adopt this table to your company's plan because it indicates quantity of major unit, total quantity, quantity of electricity, and conditions.
* Check list necessary for an estimate
-
- Use : scale, purity degree
- Partition material : wall, ceiling, floor, door, entrance of machinery
- Internal heat generation : the numbers of persons, mechanical device, exhaust of limited part, used chemicals
- Temperature/ humidity condition : summer, winter, heat source
- Operation time
- Others : Installing-related facing materials of building, accessories, water supply and distribution equipment, disinfection equipment, gas exhaust equipment, automatic fire-extinguishing alarm equipment, fire-extinguishing equipment

- The form indicates "p'yong".
- The condition of temperature and humidity is 26°C ± 2°C, 60%± 10%RH in summer, and 20°C ± 2°C, 45% ± 10% RH in winter.
|